What requirements should the IG541 fire extinguishing system meet when determining the design concentration of fire extinguishing agents?

1. The minimum design concentration for extinguishing combustible liquid fires, meltable solids fires, combustible gas fires, combustible solid surface fires, and electrical fires should be 37.5%; 2. The minimum design concentration of some combustible liquids can be determined according to Appendix B; 3. The maximum design concentration of a protected area where people work often is 43%, and it should be reviewed under the expected maximum ambient temperature conditions of the protected area. 4. When there are multiple combustibles, the design concentration of the extinguishing agent should be determined according to the design concentration of combustibles with a large number of combustibles and a high risk of fire; 5. Inertization should be used for the protection area with explosion danger The concentration can be determined according to Appendix C.

10-22 2019 10-22
IG541 fire extinguishing system combination distribution system requirements

1. Each protective area must be designed separately; 2. The design amount of fire extinguishing agent is determined according to the largest amount of fire extinguishing agent in the protective area protected by the system, and the protective area with a small amount of fire extinguishing agent should be restricted by safe concentration; 3 The selection valve can be installed upstream or downstream of the pressure relief plate. If the pressure reducing orifice is upstream of the selection valve, the length from the pressure reducing orifice to the first tee should not be less than 10 times the pipe diameter; 4. When designing the manifold of the combined distribution system, it must be on the starting line Install check valve.

10-21 2019 10-21
Which enclosed spaces are suitable for the IG541 fire suppression system?

1. Electrical and electronic equipment room. 2. Communication equipment room. 3. The state protects metal, paper and silk products and audiovisual archives in cultural relics. 4. Flammable and combustible liquid storage room. 5. Before the fire extinguishing agent is sprayed, the flammable gas fire dangerous place where the flammable and combustion-supporting gas source can be cut off. 6. Protective area where people are often working.

10-18 2019 10-18
What is the flooding coefficient?

The required IG541 volume per unit volume of the protective zone volume at the specified fire concentration and ambient temperature.

10-18 2019 10-18
What is suppression time?

Maintaining the extinguishing agent concentration specified in the design guarantees the time required to completely extinguish the fire.

10-18 2019 10-18
What is inerting concentration?

The minimum concentration of IG541 required to inertize a flammable gas-air mixture to prevent it from exploding.

10-18 2019 10-18
What is the minimum concentration for a toxic reaction?

The lowest concentration at which a physiological or toxic effect can be observed.

10-17 2019 10-17
What is the highest concentration of non-toxic reactions?

The highest concentration that had no effect on physiological or toxic effects was observed.

10-17 2019 10-17
What is the fire concentration?

The minimum volume percentage of IG541 and IG541 and air mixture required to extinguish a certain type of fire under 101.3kPa atmospheric pressure and specified temperature conditions.

10-17 2019 10-17
What is a pressure relief port?

An opening provided on the outer wall or top of the protective area to release the internal pressure of the protective area.

10-16 2019 10-16
What is a combined distribution fire suppression system?

Use one IG541 storage device to protect two or more fire protection systems.

10-16 2019 10-16
What is a protective field?

An enclosed space surrounded by a fixed enclosure and meeting the fire suppression requirements of the IG541 fire extinguishing system.

10-16 2019 10-16
What is a unit-independent fire suppression system?

Use a IG541 storage device to individually protect a fire protection system in a protected area.

10-15 2019 10-15
What is IG541 fire extinguishing system?

It consists of fire extinguishing agent storage device, fire extinguishing agent delivery pipe, valve, nozzle, alarm and control device, etc., and sprays a certain concentration of IG541 into the protective area within a prescribed time, and makes it evenly fill the entire fire protection system of the protective area.

10-15 2019 10-15
What is the inert gas IG541?

A mixed gas prepared by 52% by volume of nitrogen N2, 40% of argon Ar, and 8% of carbon dioxide CO2, referred to as IG541.

09-29 2019 09-29
What is a carbon dioxide fire extinguishing agent storage device?

The carbon dioxide fire extinguishing agent storage device is composed of a storage container, a container valve, a storage container frame, a high-pressure metal hose, a header, a safety valve, a pressure switch, a check valve, and a selection valve.

09-29 2019 09-29
What is a starter bottle device?

The starting disk device consists of a high-pressure nitrogen starting bottle, a container valve, a starting frame, and a starting pipe.

09-27 2019 09-27
Composition of high pressure carbon dioxide fire extinguishing system

The high-pressure carbon dioxide fire extinguishing system is composed of a carbon dioxide fire extinguishing agent storage device, a starter bottle device, and a pipe network system. The fire extinguishing system can work independently or interlock with the fire detection alarm system and fire control system.

09-26 2019 09-26
What is the local application system of carbon dioxide fire extinguishing system?

A fire extinguishing system that directly injects carbon dioxide at the injection rate to the protected object and lasts for a certain period of time. The carbon dioxide fire extinguishing agent is sprayed as a liquid. Applicable conditions: open space.

09-26 2019 09-26
What is a CO2 fire extinguishing system?

Within a specified time, spray a prescribed amount of carbon dioxide into the protective area and make it evenly fill the entire fire protection system of the protective area. The carbon dioxide fire extinguishing agent was sprayed in a mist form. Applicable conditions: Limited enclosed space.

1 2 3 4 5 6 7 8 9 10 ...> Total records: 345 | Pages: 18 1 2 3 4 5 6 7 8 9 10 ...>   